| Fire Alarm System in Bangladesh |
For detecting
and forecasting incidents caused by fire, there are currently three
technological variants, each of which has its advantages according to the
application requirement.
In order to
better understand the existing technologies in the market, a firm understanding
of the types of fire detection systems available is necessary, of which three
variants stand out:
-
Conventional
-
Conventional Addressable
- Adducible
analog
![]() |
| Conventional Fire Alarm System Bangladesh |
Conventional
Systems in Bangladesh
Conventional
fire alarm panels work by zones and have a capacity set by each manufacturer,
ranging from 1 to 100 zones. Basically, an area consists of some or all of the
accessories of action or control of an area or floor of a building. When
talking about action, it refers to the elements that inform the panel of a fire
situation, including a fire warning lever or different types of detectors.
Some control
panels allow scalability in their architecture, allowing the increase of the
number of zones by means of expansion modules, which makes it possible to
increase the system both in the number of initiation and indication areas.
In this way,
the main characteristics of the Conventional Systems are the following:
- Low
initial cost of equipment.
- Wide range
of compatible devices.
- Simple
programming.
- Suitable for
low and medium installations.
- Only for
detection, little integration.
Conventional
Addressable System in Bangladesh
The
addressable panels arose from the need for a better identification of the place
or area where a fire alarm signal was produced, for which a specific technology
had to be developed. This new technology allowed manufacturers to incorporate
and mix on an SLC circuit (Signaling Line Circuits), now called loop and no
longer zone, a greater number of alarm warning accessories, by counting the
panels with the possibility of identifying which accessory specific is sending
the signal to the panel. These accessories are called points.
![]() |
| Addressable Fire Alarm System in Bangladesh |
The point
capacity of an addressable system is determined by the amount of SLC it
contains and by the number of points that each of these loops allows. Again,
according to each manufacturer, there may be panels with one or more ties.
Thus, the
main characteristics of the Conventional Addressable Systems are:
- Easy
installation.
- More
information on the state of the system on the panel and the central station
(event log).
-
Programming of inputs and outputs very flexible.
- Greater
capacity for expansion and integration.
Analogue
Addressable System in Bangladesh
In this type
of systems the detectors become sensors that transmit, in addition to their
address to the control panel, the information corresponding to how much smoke
or heat is registered. Once the control panel has been programmed, it will take
the decision to give an alarm based on the information received, when it does
not match the parameterized values.